This scanning radio has been manufactured so that it will not tune to the radio frequencies assigned by the FCC for cellular telephone usage. BCDT. BCDT – Click image to view in full. Uniden’s Base/Mobile Digital . Easier to Read BCDT/UBCT Manual · BCDT User Manual · Control. BCDT – read user manual online or download in PDF format. Pages in total:

Author: Vunris Vikus
Country: Congo
Language: English (Spanish)
Genre: Life
Published (Last): 10 December 2008
Pages: 253
PDF File Size: 19.64 Mb
ePub File Size: 14.72 Mb
ISBN: 155-1-26871-156-6
Downloads: 49415
Price: Free* [*Free Regsitration Required]
Uploader: Maunos

This trunking scanner trunktracks the following types of systems: If you turn this feature on, the scanner mutes, starts Close Call Only mode, and stores any Close Call hits from the bands selected in ‘ Set CC Bands ‘ up to the maximum you specified in the ‘ Max Auto Store ‘ setting. The default setting is AFS. How to view these pages in your browsers I have formatted these bcf996t so that you can view them with any monitor, in any browser Opera, I.

Press and hold 7 Att for global attenuation.

Trunktracking is searching for all IDs in a system same concept as searching for frequencies in a band. To Program a New Channel press Menu.

These steps work only when you can clearly receive the conventional system or trunked site. Those entries that say System Voice: To hold on a CC hit press Hold. Head – Indicates the selected heading to the designated Dangerous Crossing from any direction.

To start Weather Alert p ress then WX. You can also lock out this subfleet ID so you will not bc9d96t it.

The Scroll Control is a dual purpose control. Copyright Universal Radio, Inc. This should let you get started quickly to enjoy your new scanner. If you set an incorrect decode threshold level in Bcd99t 5, the scanner might stop decoding all digital signals in the site.

  HELICOTYLENCHUS MULTICINCTUS PDF

Set Location Info enter the latitude and longitude for the location. Pri – Close Call checks for frequencies every two seconds. Set Data Skip with the nanual set to on, when it receives a data signal, manula scanner stops briefly on the channel, then immediately resumes scanning automatically. Page 91 On — the scanner outputs the signal. Now listen to the communications.

If you receive an alert it will be at FULL volume. You can tell which block a Motorola ID is in by its number.

Once the threshold level settles to a stable setting make a note bcd996f the value. Specifying The Correct System Type With a repeater based system, the repeater is located on top of a tall building kanual on a radio tower that provides great visibility to the area of operation.

Set Attenuator Choose to attenuate all frequencies manuao about 20 dB. These are the settings you should look at before you perform a quick searchclose call searchsearch and storeor close call auto store.

Active IDs will appear in the display. What Is Searching Set Lockout determines whether a channel will be scanned or not.

You can still do that separately if you really want to confuse yourself. To program text you must first program the system, site, group, channel, location, custom search, Tone-Out, or SAME group. For Custom rebanded Motorola Systems Requires firmware 3. P25 Waiting Time Requires firmware 3.

Reviewing Locked Out Frequencies: Marked Channel manuzl The scanner only sends the audio for channels that have the record option turned on to the REC jack. Otherwise, to cancel, press [MENU]. Oruse Menu to drill down to the channel options and lock it out there.

  ASTERIX DER GALLIER COMIC PDF

Program these systems as a Motorola system and let the scanner detect the digital.

Uniden BCD996T User Manual

If the ID has not been stored, it stores the ID into a created group named ‘ Found Channels ‘, then resumes searching. In addition, certain special regions and wildcard settings can be assigned. Motorola systems are limited to a maximum of 28 frequencies per system or site.

Scroll to ‘ DMS: A receiver with coded squelch only activates when the received signal has the correct ‘code’. The items below in Blue do not follow the radio’s menu order because IMHO they should be in the following order to properly setup and use the Close Call features.

Easier to Read BCDT/UBCDT Digital Scanner Manual

If no programmed location is displayed ‘ OFF ‘ in the displayyou will only be able to toggle ‘Data Display’ and the current ‘Location Display’. For each alert in the scanner, you can select from 9 different tone patterns, and 15 volume settings.

Los Angeles, CA Manuzl. Press Hold again to release hold mode and start searching. To enter a letterturn the scroll control until the character you want appears. The ‘Automatic Channel Setup’ allows you to enter a frequency without having to change a step size setting. Santa Fe, NM Area. You have to program the trunking system and site first.