DANFOSS EKC 102 A PDF

EKC Series – chennai india, EKC Series – chennai, EKC Series – , general ac EKC Series – , EKC Series – , ERC Series – chennai tamil . RI8NB R INSTRUCTIONS. EKC D (B). R Type: Pt Instructions RI8NB © Danfoss 05/ EKC D. EKC B Controller with two relay outputs, extra temperature sensor and digital EN and EN , A2 Weight = g Danfoss can accept no.

Author: Doujora Shaktizahn
Country: Jamaica
Language: English (Spanish)
Genre: Medical
Published (Last): 10 January 2007
Pages: 364
PDF File Size: 15.25 Mb
ePub File Size: 16.84 Mb
ISBN: 780-9-33252-243-5
Downloads: 85977
Price: Free* [*Free Regsitration Required]
Uploader: Tumuro

Danoss will be change-over to the normal time delay A03 when the temperature has dropped below the set upper alarm limit. Remove products Compare products.

When the defrost starts the danfows timers are set at zero. Delay on outputs during start-up Other displays: The extra temperature signal can be used for product sensor or for condenser sensor with alarm function.

HVAC Danfoss Electronic Temperature Controller type Danfoss EKC 102A 084B8500 for Freezer

Activation can take place via r39 or input DI Alarm The controller can give alarm in different situations. The controller will then start a defrost cycle.

DO3 is a 8 A relay. And for how long it at least has to be stopped. After the time delay the second compressor will be cut in.

Sensor error on S5 E Relays The general connections are: Defrosting S20 Emergency cooling S25 Manual control of outputs S32 Delay of output at start-up non The defrost temperature cannot be displayed. A-alarms will not become visible until the set fkc delay has expired.

See the significance in the Fault Message section. Normal function where the relay cuts in when refrigeration is demanded 1: The function will be active after each and every power failure. S5 is a defrost sensor and is used if defrost has to be stopped based on temperature. Saux is an extra sensor for measuring fx. A controller only contains this part of the functions.

  ALLAN DELAIR CATACLYSM PDF

HVAC Danfoss Electronic Temperature Controller type Danfoss EKC A B for Freezer

Push the upper or the lower button and find that parameter you want to change 3. All starting methods will function in the controller. A special moulding technique unites the hard danfiss plastic, the softer buttons and the seal, so that they become an integral part of the front panel. R22 Medium and high temperature scroll air-cooled condensing unit Box type air outlet from side scroll ZB series.

HVAC Danfoss Electronic Temperature Controller type Danfoss EKC 102D 084B8506 for Freezer

Here are the messages that may appear: When the value is passed, a defrost will start. The function is furthermore only relevant if you have chosen defrost with interval 1102 d There is no sensor -d-: The interval time is not active when set to 0.

When the compressor is stopped, it must remain stopped for at least x minutes. The abovementioned does not influence compliance with the right to process data, which was performed on the basis of the consent expressed by you, before you withdrew it. Regulation is carried out when the input is short-circuited, and regulation is stopped when the input is put in pos.

HVAC Danfoss Electronic Temperature Controller type Danfoss EKC D B for Freezer

The digital input can be programmed to. Carton box Delivery Time: Interval between defrost starts The function is zeroset and will start the timer function at each defrost start.

The set value can be locked or limited to a range with the settings in r02 and r Please refer to literature no.

  JBC CATALOGO PDF

Select your own number. Dandoss and packing are imbedded in the front. To avoid a too low setting of the setpoint, the min. Start-up After a power cut the system can be started with a defrost.

When the controller demands refrigeration it will first cut in the compressor with the shortest operating time.

However the view of —d- will be discontinued if: If the settings in the controller are to be protected with an access code you can set a numerical value between 0 and RA Box type air outlet from side Medium and high temperature scroll air-cooled condensing unit danfows ZB series.

Defrosting S15 Defrost sequence. EKC for panel mounting danfiss EKC for DIN-rail mounting have been specially developed for control duties in refrigeration plant so that operation, setting and programming are optimised and simplified as much as possible. Skc stopped by thermostat S DI input is open S The function delays the interval time d03 by the set number of minutes, but it only does it once, and this at eic very first defrost taking place when voltage is connected to the controller.

If there are several, you can continue pushing to see them. It will cut out again when the temperature comes down to the set reference. Defrost can be accomplished with electricity or natural defrost. The Danfoss controller is used for applications where temperature is critical.